Sincerity Is Fundamental, Clients Is The First.

 

Strict Quality Control, Earnest Service Supply.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsFault Current Indicator

35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable

I'm Online Chat Now
Certification
China Beijing Tianyihongda Science & Technology Development Co., LTD certification
China Beijing Tianyihongda Science & Technology Development Co., LTD certification
Super friendly service, the Power Line Fault Indicator high quality as expected and very economy and environmental protection.

—— Bruce

This is the first time i do Underground Cable Fault Indicator business , after i received , it is work well. and now i want to order more.

—— Joseph

35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable

35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable
35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable 35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable

Large Image :  35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable Get Best Price

Product Details:

Place of Origin: China, Beijing
Brand Name: TYHD
Certification: type test report
Model Number: TYHD-3

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: Negotiation
Packaging Details: stanadard export package
Delivery Time: 3-5 working days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 3000 sets/month
Detailed Product Description
Long Endurance Current: 650A Auto Reset Time: Transient Fault,auto Reset By Setting Time
Function: Indicate And Detect Short-circuit And Eath Fault Measurement Accuracy: 0~600A:±3A Or3%
Optical Fiber Communication Distance: 15m Optical Fiber Data Rate: 9600bps
High Light:

remote current indicator

,

ground fault current transformer

35KV optican fiber communicable fault locators and Fault circuit indicatos withdata controlling box for cable

 

one whole system is composed of 1 panel indicator , three short-circuit indicator .one earthed indicator and one data transmission unit, the communication protocal is IEC101 OR IEC104.

 

Part 1: Panel indicator
1. Summary
 
TYHD-1 panel type fault indicator(be called indicator for short below) is mainly used for indicate short circuit fault and earth fault on the On/Off panel, and used for output wireless signal.

 

Data transmission Unit is applied in power distribution network, used for data gathering and transmission for load detection ,fault detection and location in cable.
 
2. Working principle
 
The principle is micro-controllers with little power consumption, micro-controllers can automatically identify fault signals from short circuit indicator and earth indicator, They can display the fault signals using LED flashing lights on the spot and output the signals by wireless.

Date Transmission Unit is to make photoelectric translation,process and analyze the fault signal from short-circuit fault indicator and earth fault indicator transmitted through optical fiber.then send the fault signals to master station by GSM or GPRS after analysis and processing to realize fault detection,fault location and load current measurement of power distribution network .

 

 
3.Installing methods
The appearance of the indicator :
35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable 0
                            FRONT VIEW
35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable 1
                                                                      BACK VIEW
 
Specification of installing:
L1 is connect with A live line
L2 is connect with B live line
L3 is connect with C live line
L4 is connect with Earth line
V1.08 is the version number of software
 
3.1 Fault indicate function
The lights on the L1,L2,L3,and Earth buttons will flash with a 5-minutes interval,if the short circuit fault or earth fault occur.This can be returned to the original condition automatically according to the time delay set by the factory or by pressing button of “Reset/Test” manually.the low battery capacity of the indicator is show on the panel by wireless,The indicator of low battery voltage will flash at the same time(with 4 seconds interval).
 
3.2 Reset/Test function
Restore:press the “Reset/Test” button slightly,then restore after all lights have light.
Self-checking:

Address black point means the corresponding LED is on
L1(1) L2(2) L3(4) E(8)
1
2
3
4
5
6
7
8

3.3The method of changing battery
35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable 2                          35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable 3
 
Take off battery as Chart 1 and Chart 2,then exchange.
Take off the battery and replace the new battery follow the picture1 and picture 2
4.Function
4.1 Show short circuit fault and earth fault locally.
4.2 Self-reset ,the interval time of self-reset can be set before delivery from factory (The default is 12 hours).
4.3 Reset or self-test manually.
4.4 Set the addresses of the indicators
5.Performance index
5.1 The distance of fiber communication:
Typical value:5m;Max:10m
5.2 Ambient temperature:-35℃~70℃
5.3 Action times :more than 2000
5.4 Indicator power supply mode :built-in 3.6V/2Ah lithium cell.
5.5 Battery can be changed.
5.6 Life length: continuous working for more than 10 years.
5.7 net weight :less than 0.5kg
5.8 Static power consumption :less than 12uA
Part 2 :The cable indicator of short circuit fault
1.Summary
The TYHD-1cable indicator is suitable for the cable 35kV system (including bellow 35kV system).It can indicate while there is short circuit ,measure electric current,measure temperature(temperature probe attached) and transmit data.It can help line finder find the fault quickly .shorten power-off time,improve the reliability of power supply,be convenient for users to monitor the load current of line on real time.The picture of product is below:
The TYHD-1cable indicator of short circuit fault.
2.working principle
The principle is clip-on line sensor and intelligent controller . The intelligent controller control as the core with little power consumption ,The clip-on sensor can measure the load current on real time,and transmit the current data by fiber timing. When a circuit has a short circuit fault,The cable short circuit indicator recognize it automatically ,then judge intelligently ,then display locally.At the same time transmit the action signal to the panel type indicator installed locally by fiber,which can display locally on the panel .Of course,It can transmit the data to fiber type monitoring terminal by data remote interface,realizing the remote transmission of fault signal and measured data.
3. Installing methods
35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable 4
 
3.1 Clip the indicator on the line as shown in the pictures1.2.3
3.2 Connect the data remote interface of the indicator to fiber transmitting terminal by short-distance fiber.
3.3 Connect pulse port of the indicator to panel type indicator by fiber.(the pulse port not needed to connected without panel indicator)
35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable 5
Note:
Put the fiber to the end,and tighten the nut.
The length of the fiber should be less than 15m,The shorter the distance ,the higher the reliability .
The fiber section is cut flat with a paper cutter, which is beneficial to the transmission of fiber signal
After the test completely cover the rubber cover,in order to avoid abnormal indicator accused by long-term light leakage
4.Function
4.1 Install and disassemble easily,be suitable for Cable lines with a diameter of less than 40 meters.
4.2 The short circuit fault can be found.
4.3The line load current can be detected in real time.
4.4The faults can be indicated locally by flashing.
4.5Epoxy pouring,fully sealed structure,can run outdoors for a long time.
4.6 Tracking the load current automatically without any setting.
4.7Reset automatically,the time can be set before delivery.
4.8 Inhibiting the closed current automatically.
4.9Fiber data communication:

Indicating locally by transmitting the action message from fault indicator to panel indicator(no panel indicator is not available).
Translating remotely by translating load current and action message to cable terminal by fiber.
4.10 Take the power from the circuit current and the built-in backup lithium battery.
5. Performance index
5.1Environment index:
environment temperature:(-40~70)℃ maximum daily temperature difference is 25℃.
relative humidity:5~95%
altitude height:<2000m
5.2 System specification
cable outer diameter: 10~40mm
system voltage:≤35kV
system frequency:50Hz
maximum over-current protection time delay adaptable :<10S
5.3 Main technical performance and parameters

working power:taking electricity from line sensing current, one 3.6V/2Ah lithium battery is equipped for supply;
static power consumption:3.6V power supply<18uA
designed life:10 years
measurement accuracy:0~600A:±3A or3%
optical fiber communication distance:15m
optical fiber data rate:9600bps
long endurance current:650A
auto reset time:transient fault,auto reset by setting time(defaulted 24h);
permanent fault:Power off duration is over 10 minutes and it is in alarm state, auto reset after power restore within 1 minute. If power off duration is exceeding reset setting time,reset by setting time.
short endurance current:20kA/4S
weight:<0.5kg

Part 3: cable earthed fault indicator

3.1 Summary

TYHD-1 cable earthed fault indicator is applied to cable system below 35KV, with function of zero-sequence current measurement and data transmit function, it indicates fault when earth fault happened in cable, It can help line finder find the fault quickly .shorten power-off time,improve the reliability of power supply,be convenient for users to monitor the zero-sequence load current of line on real time.The picture of product is below:


35KV Communicable Fault Current Indicator , Data Controlling Box Ground Fault Current Transformer For Cable 6

 
 

3.2 working principle

Using specially designed open zero-sequence CT as sensor of measuring zero-sequence current, micro-power consumption intelligent controlling chip is as core to real-time measure zero-sequence current online and timely transmit current data measured through optical data interface. When earth fault happen, indicator will automatically distinguish fault current characteristics to judge earth fault intelligently, then transmit the data through “data remote transmit interface” and “panel indicator interface”connecting to DTU and panel indicator through the plastics optical fiber to realize remote transmitting for fault signal and measured data.

      The parameters can be customzied by clients' requirements. please contact beijing tinanyihongda Sceince & Technology Develoment cooerpation limted for more details of fault indicators and data transmission unit.

 

3.3 Functions and Characteristics

4.1 Install and uninstall simply.adaptable to detect zero-sequence current in three-phase cable with outer diameter below 110mm.

4.2 Epoxy resin casting,adaptable to run outside in a long term.

4.3 Real-time detect zero-sequence current.

4.4 detect earthed fault

  • Used for low resistance grounding system:zero-sequence current starting value adjusted range is 10-200A before delivery,default value is 30A;delay time range can be adjusted as 50mS~60S before delivery, default value is 200ms.when zero-sequence current is above current starting value and lasting time is above delay setting time then it can be judged as fault.
  • Used for low current earthed system: detect special signal and meet fault judgement condition then judged as earthed fault.

  

Contact Details